63A RCCB
63A RCCB

63A RCCB

MOQ : 10 Units

63A RCCB Specification

  • Rated Short Circuit Breaking Current
  • 6kA
  • Breaking Capacity
  • 10kA
  • Phase
  • Single/Three Phase
  • Rated Short Circuit Making Current
  • 6kA
  • Mechanical Life
  • >4000 Cycles
  • Product Type
  • RCCB (Residual Current Circuit Breaker)
  • Installation Options
  • Din Rail Mounting
  • Function
  • Earth Leakage Protection
  • Poles Number
  • Double Pole (DP)
  • Rated Voltage
  • 230/415V AC
  • Rated Current
  • 63A
  • Rated Frequency
  • 50/60Hz
  • Curves
  • B Curve
  • Temperature Protection
  • -5C to +40C
  • Weight
  • Approx. 280g
  • Color
  • White & Blue
  • Trip Time
  • <0.1s
  • Standards Compliance
  • IS 12640/IEC 61008
  • Operating Voltage Range
  • 0.8 to 1.1 Un
  • Sensitivity (Rated Residual Operating Current)
  • 30mA
  • Contact Position Indicator
  • Yes
  • Mounting Orientation
  • Vertical
  • Relative Humidity
  • Up to 95% RH (non-condensing)
  • Terminal Capacity
  • Up to 25mm2
  • Degree of Protection
  • IP20
 

63A RCCB Trade Information

  • Minimum Order Quantity
  • 10 Units
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 100 Units Per Month
  • Delivery Time
  • 10 Days
  • Main Domestic Market
  • All India
 

63A RCCB About



Discover the Special 63A RCCB-an enlightened solution for advanced electrical protection. Engineered as a true masterpiece, this affordable device offers inestimable safety at an unbeatable price. Conforming to IS 12640/IEC 61008 standards, it provides earth leakage protection with a highly sensitive 30mA threshold. Key features include a robust double pole design, rapid trip time under 0.1 seconds, a contact position indicator, and a durable DIN rail mounting system. With up to 95% RH tolerance and versatile phase support, it ensures optimal safety for homes and industries across India.

Wide Range of Application and Practical Usage

The 63A RCCB is ideal for residential, commercial, and light industrial locations, providing vital protection against earth leakage and electric shock. Designed for vertical mounting, its simple installation on a Din Rail streamlines the setup process. Its application extends to single or three-phase distribution boards in homes, offices, factories, and schools. Direct usage involves connecting to circuits where inestimable safety is paramount, making it a pivotal component in modern electrical infrastructure.


Efficient Supply Chain and Export Details

The 63A RCCB is supplied from India's major FOB Ports, ensuring prompt international deliveries. Our main export markets include the Middle East, Africa, and Southeast Asia. Every product is carefully dispatched in secure, industry-standard packaging to minimize risk during transport. The expenditure for such specialized safety equipment is managed efficiently, ensuring buyers receive excellent value and reliable shipment tracking, supported by a robust supply chain network.


FAQ's of 63A RCCB:


Q: How does the 63A RCCB enhance electrical safety?

A: The 63A RCCB promptly disconnects the circuit in case of earth leakage or faulty currents, minimizing the risk of electric shock and fire, and thereby guaranteeing superior electrical safety for users and property.

Q: What is the process for installing the 63A RCCB?

A: Installation is straightforward-mount the RCCB on a DIN rail in a vertical orientation, connect it according to the wiring diagram provided, and ensure all terminals are securely fastened. Professional installation is recommended for safety.

Q: Where can the 63A RCCB be used effectively?

A: This RCCB serves residential spaces, commercial buildings, offices, factories, and educational institutions-anywhere that demands reliable earth leakage and overload protection in single or three-phase power systems.

Q: When should I consider using a 63A RCCB?

A: You should use a 63A RCCB when protecting circuits with a risk of earth leakage current, particularly in areas with high humidity or increased hazard potential, to ensure uninterrupted and safe power supply.

Q: What are the benefits of the contact position indicator?

A: The contact position indicator offers clear visual confirmation of the RCCB's ON or OFF state, allowing for efficient monitoring and safer maintenance procedures.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Motor protection circuit breaker Category

Schneider Electric Residual Current Breaker

Schneider Electric Residual Current Breaker

Minimum Order Quantity : 10 Units

Rated Short Circuit Breaking Current : 6 kA

Product Type : Other, Residual Current Breaker

Function : Residual Current Protection

Breaking Capacity : 10 kA

Weight : 340 g

Schneider Electric Residual Current Circuit Breaker

Schneider Electric Residual Current Circuit Breaker

Minimum Order Quantity : 10 Units

Rated Short Circuit Breaking Current : 6000A

Product Type : Other, Residual Current Circuit Breaker (RCCB)

Function : Residual Current Protection

Breaking Capacity : 10 kA

Weight : 275 g

XC60 Schneider Electric Miniature Circuit Breaker

XC60 Schneider Electric Miniature Circuit Breaker

Minimum Order Quantity : 10 Units

Rated Short Circuit Breaking Current : 6000A

Product Type : Other, Miniature Circuit Breaker

Function : Overload and short circuit protection

Breaking Capacity : 6 kA

Weight : Approx. 120 g (per pole)

1A Schneider Electric Miniature Circuit Breaker

1A Schneider Electric Miniature Circuit Breaker

Minimum Order Quantity : 10 Units

Rated Short Circuit Breaking Current : 6000A

Product Type : Other, Miniature Circuit Breaker (MCB)

Function : Overcurrent and Shortcircuit Protection

Breaking Capacity : 6kA

Weight : Approx. 120g



Back to top